1. Count the flashes
On Chamberlain and LiftMaster openers, the lights tell you what's wrong. 10 flashes means a safety sensor problem: misaligned, dirty, blocked or in direct sun (Chamberlain Group support: lights flash and the door won't close; LiftMaster 8550W/8557W user's guide 114A5013, 2017 (FCC copy)).
Other counts mean different things on different models, so check the chart in your opener's manual. On some models Chamberlain says 2 flashes means the LOCK button on the wall control is on (press and hold LOCK for about 2 seconds, until its light stops flashing, to turn it off), and 5 flashes that the door hit something and reversed (Chamberlain Group support: lights flash and the door won't close; Chamberlain Group support: door reverses or won't fully close). LiftMaster's 2017 guide uses 5 flashes for a timed-out programming step instead (LiftMaster 8550W/8557W user's guide 114A5013, 2017 (FCC copy)).
2. Check the safety sensors
- Find the two small sensors near the floor, one on each side of the door, no higher than 6 inches up (Chamberlain Group support: lights flash and the door won't close; DASMA Technical Data Sheet #167 (revised Apr 2023): garage door and opener checklist for home inspectors and consumers).
- Wipe both lenses and move anything in the beam's path.
- Look at their lights. Chamberlain: the receiving sensor has the green light and the sending one the amber light (Chamberlain Group support: lights flash and the door won't close).
- Amber steady but green flickering? The sensors are usually blocked or out of line: align them (steps below). Still blinking after that? Do the same with the amber one (Chamberlain Group support: troubleshoot safety sensors that are off or flicker; LiftMaster 8550W/8557W user's guide 114A5013, 2017 (FCC copy)). Green fully off? On some Chamberlain sensors that points to its wire (below).
- A light still won't come on? Look at the thin sensor wires for a cut, a staple through them or a loose end. Chamberlain lists a broken or shorted wire and a faulty sensor as the other causes (Chamberlain Group support: troubleshoot safety sensors that are off or flicker); a damaged wire is a job for a garage door company (our rule).
Low sun? Bright sunlight straight into the receiving sensor can stop it seeing the beam, so the opener thinks something's in the way. That's why it can be worse at certain times of day (Chamberlain Group support: lights flash and the door won't close). How to make a free sun shield is further down this page.
2b. How to align garage door sensors
Chamberlain, LiftMaster and Craftsman, in Chamberlain's order (Chamberlain Group support: how to align safety reversing sensors):
- Find both sensors on the tracks and clear the beam.
- Loosen the wing nut on the receiving sensor (the one with the green light).
- Point both lenses straight at each other.
- Tighten the wing nut once the green light glows steadily. Both lights solid means they're lined up.
- Test the door with the remote or the wall control.
On Chamberlain's 2021 sensors (model 041-0136): both lights off points to a wiring problem on the sending (amber) side; amber on and green off, a wiring problem on the receiving side; green blinking, out of line or blocked (Chamberlain Group support: how to align safety reversing sensors).
Genie (from its 2024 manual; older models may differ): the sensor with the red light sends the beam and the one with the green light receives it (Genie belt and chain drive opener manual (Oct 2024), printed page 18). Genie says to wipe the lenses with a clean cloth and make sure the sensors face each other: they must be able to "see" each other (Genie: garage door won't open or close? Try these tips (Oct 18, 2021; read Nov 18, 2026)). Re-aim until both lights are on steadily, which Genie's chart calls normal. Red blinking twice with green on means the beam is out of line or blocked, or a sensor has failed; red blinking twice with green off points to the green sensor's wire, or a failed sensor (Genie belt and chain drive opener manual (Oct 2024), printed page 18). Genie's full light chart: Genie blinking lights.
Safety while you aim. Chamberlain's page says to disconnect power before installing or adjusting sensors (Chamberlain Group support: how to align safety reversing sensors), yet its steps use the green light, which needs power. Our advice: if you can reach the opener's plug without standing under the open door, unplug it while you loosen and move the sensor, then plug it back in to check the light. Unplugging doesn't stop an opener with a backup battery, so on those, and whenever it's plugged in, keep the wall control, every remote, keypad and phone app away from others, keep everyone away from the door, and don't press any button until you're done. Never disable or bypass the sensors: Chamberlain calls them a required safety device that must not be disabled (Chamberlain Group support: how to align safety reversing sensors).
3. Need it closed right now?
On many openers (Genie, and Chamberlain and LiftMaster openers made up to February 3, 2022), you can usually close the door by pressing and holding the wall button until the door is fully down (LiftMaster 8550W/8557W user's guide 114A5013, 2017 (FCC copy)). Chamberlain says newer openers don't have this feature (Chamberlain Group support: lights flash and the door won't close). With this override the door won't reverse for anything in its way. Watch the door all the way down, and keep everyone clear.
Stop and call if…
- The sensor wires are cut or damaged (Chamberlain lists wiring faults among the causes)
- The door is crooked, a cable is hanging, or you heard a loud bang. Read cable snapped or broken spring
- The door still reverses with nothing in the way after you've aligned the sensors and, on a door that looks sound, reset the down travel by your opener's manual (see "Door touches the floor, then goes back up" on this page). Never raise the force setting to push through it. If the 2x4 test fails, stop using the opener
After any fix, do the monthly 2x4 test: lay a 2x4 flat under the door and close it. It should touch the board and go back up. LiftMaster says to test it every month (Chamberlain support: how to test the safety reversal system; LiftMaster 8550W/8557W user's guide 114A5013, 2017 (FCC copy)).
Sources
- Chamberlain Group support: lights flash and the door won't close
- Chamberlain Group support: troubleshoot safety sensors that are off or flicker
- Chamberlain Group support: how to align safety reversing sensors
- Genie belt and chain drive opener manual (Oct 2024), printed page 18
- Genie: garage door won't open or close? Try these tips (Oct 18, 2021; read Nov 18, 2026)
- Chamberlain Group support: door reverses or won't fully close
- Chamberlain Group support: what would cause the door to come down, hit the floor and reverse?
- Chamberlain support: how to test the safety reversal system
- LiftMaster 8550W/8557W user's guide 114A5013, 2017 (FCC copy)
- DASMA Technical Data Sheet #167 (revised Apr 2023): garage door and opener checklist for home inspectors and consumers