Home / Guides / Reset the travel limits

Garage door stops short or reverses? Reset the travel limits

The travel limits are the two points where the opener stops the door: fully open and fully closed. If they drift, or the floor or the seal along the bottom of the door changes, the door can stop short or go back up when it reaches the floor.

You'll need a step ladder.

First: find your model, and check the door itself

Find the model number on the label on the motor unit (the box on the ceiling). You'll need it to pick the right steps below.

Resetting the limits only helps if the door runs freely. With the door closed, look from the floor:

Before you start

  • Keep everyone, and the car, out from under the door while you work
  • Set the ladder to one side of the opener, out of the door's path. The door, the rail and the arm move while you hold the buttons, so keep your head and hands clear of them and watch the door the whole time
  • Genie says not to run its openers from the wall button until the limits are set (Genie: how to set the up and down travel limits of your Genie opener (Nov 2, 2021))

LiftMaster and Chamberlain with an Adjust button and UP/DOWN arrows

Use these steps if your opener has an Adjust button and UP and DOWN arrow buttons, and its model number does not end in "MC". These are Chamberlain's steps for its Security+ 2.0 and myQ openers (Chamberlain Group support: how to program the travel on a Security+ 2.0 and myQ opener). Models ending in MC have their own setup guide from Chamberlain.

  1. Press and hold the Adjust button until the UP arrow flashes or you hear a beep.
  2. Hold an arrow until the door is where you want it fully open. Press and release Adjust. The lights flash twice.
  3. Hold an arrow until the door is where you want it fully closed. Press and release Adjust.
  4. Press and release the UP arrow. The door opens to the new open position.
  5. Press and release the DOWN arrow. The door closes to the new closed position. Done.

If the lights flash 5 times, the steps timed out: start again. If they flash 10 times, the safety sensors (the two small boxes near the floor, one each side of the door) are blocked or out of line. Chamberlain says openers made after 2022 don't flash 10 times; check that both sensor lights are on instead (Chamberlain Group support: how to program the travel on a Security+ 2.0 and myQ opener).

Chamberlain and LiftMaster with a black button and a purple or yellow button

These are Chamberlain's steps for openers with these two buttons on the motor unit (Chamberlain Group support: program the travel and force limits (black and purple or black and yellow buttons)).

  1. Hold the black button until the light flashes slowly, then let go.
  2. Hold the black button until the door is open as high as you want. Check it clears your car.
  3. Press the remote or wall button. The door starts to close; as soon as it moves, press and release the black or purple/yellow button to stop it.
  4. Hold the purple/yellow button until the door is where you want it closed.
  5. Press the remote or wall button. The door opens.
  6. To set the force, press the purple/yellow button twice, then run the door down, up and down again with the remote.

Genie openers with SET/PRGM and arrow buttons

These are Genie's steps. Genie says to do them with the opener plugged in, any backup battery taken out, and the door part-way open. Each step times out after 30 seconds (Genie: how to set the up and down travel limits of your Genie opener (Nov 2, 2021)).

  1. Press and hold the DOWN arrow until a light turns blue, then let go. It flashes blue.
  2. Hold the DOWN arrow until the door is fully closed and the rubber seal along the bottom just squeezes against the floor. Don't press so far that the door bends.
  3. Press and release SET/PRGM. The lights flash blue, then go off.
  4. Press and hold the UP arrow until a light turns blue, then let go.
  5. Hold the UP arrow until the door is fully open, then press and release SET/PRGM. On a door that folds up in panels (most do), stop before the part that slides along the rail reaches the motor unit, and don't let the door pull the spring cables tight.

Older openers with adjustment screws

Some older openers set the limits with screws on the side of the motor unit instead of buttons. Follow the owner's manual for your model, or ask a technician.

Always finish with the reversal test

Chamberlain says to do this test after any change to the limits (Chamberlain Group support: how to program the travel on a Security+ 2.0 and myQ opener; Chamberlain Group support: how to test the safety reversal system). Open the door, lay a 2x4 flat on the floor under the middle of the door, and close it. The door must touch the board and go back up. If it doesn't, stop using the opener and call a technician. Genie's page on limits doesn't describe a test, but its installation guides put a 2x4 test right after the limit steps (Genie: screw-drive opener installation guide (limit programming and the 2x4 contact-safety test)). We suggest the same test on any make, once a month.

When to call a technician

  • The limits won't hold, or the door still reverses after you reset them
  • The door is heavy, crooked or noisy, or a spring or cable looks wrong
  • The reversal test fails

Not sure what it is? The door checker asks what you see and points to the likely cause. Flashing lights on the opener? See LiftMaster and Chamberlain flashing codes or Genie blinking lights.

Getting a repair quote? Compare it with typical prices, with their sources, or put it into the free quote checker.

What you can do today

  • A free second opinion on a quote you already have. Text the amount and what it covers (or a photo of the quote) to (918) 205-5200; we compare it with published price data (the sources on our price page), and text you back within a business day.

Diagram: Two monthly safety tests: the 2x4 test and the sensor test

Labeled diagram in two parts. First, the 2x4 test: a 2x4 lies flat on the floor, centered under the open door; when the door closes and touches it, the door must go back up. Second, the sensor test: a box sits in the doorway between the two safety sensors; when you press the remote to close, the door should move an inch at most and the opener lights flash. If either test fails, stop using the opener until it's adjusted, repaired or replaced. Only test a door that hangs straight with tight cables.Labeled diagram in two parts. First, the 2x4 test: a 2x4 lies flat on the floor, centered under the open door; when the door closes and touches it, the door must go back up. Second, the sensor test: a box sits in the doorway between the two safety sensors; when you press the remote to close, the door should move an inch at most and the opener lights flash. If either test fails, stop using the opener until it's adjusted, repaired or replaced. Only test a door that hangs straight with tight cables.
Only on a door that hangs straight with tight cables. Test both once a month. If the door doesn't go back up from the 2x4, or comes down with the box in the way, stop using the opener until it's adjusted as its manual says, repaired or replaced. Sources: Chamberlain Group support: how to test the safety reversal system; Chamberlain 1345M owner's manual: test the protector system (manual copy); CPSC Publication 523. Free to reuse; please credit us: how to use our diagrams.
Straight answers

Who will answer

Tulsa Garage Door Help is a garage door guide and price site, not a repair company. We're signing up one insured, registered local garage door company that will agree in writing to the promises on this page. We check its insurance certificate and its Oklahoma business registration ourselves, and we'll show you what we checked and when. Until it's confirmed, we're not taking repair requests. The free second opinion on a quote, by text, is open now.