The remote or keypad won't close the door, but holding the wall button does
The likely cause, a quick check, what's safe to do, and what it usually costs.
Most likely: Safety sensor fault: remotes are refused, held wall button overrides
Chamberlain describes exactly this split when the sensors are not working. Genie's manuals describe the same: remotes won't close the door while the sensors have a fault, but holding the wall button can (see the note below).
You can usually fix this yourself.
Also possible
- Sensor wiring or a failed sensor. Sensor light stays dark however it is aimed. Needs a pro
- Wall control LOCK or vacation mode is on. Remote does nothing in either direction; on Chamberlain-family openers the lights flash twice (check your manual's chart). DIY
Safe to do now
- Clear the doorway. Both lights on the safety sensors (the two small boxes near the floor) should be steady.
- Only at some times of day? See The door won't close at certain times of day, usually when the sun is low.
- Re-aim and tighten any sensor that has been knocked.
- Turn LOCK or vacation mode off at the wall control if it is on.
- If you hold the wall button to close, clear the doorway and watch the door all the way down.
Don't
- Do not bypass the sensors so the remote works again.
- Do not keep reprogramming the remote; it is not the fault if it still opens the door.
Typical price
If it's the most likely cause: Often free: you can usually sort this yourself.
If it turns out to be one of the others:
- Opener repair: typically $124–$368 (average $234). Source: HomeAdvisor (no date shown).
National figures, not a quote. Every price range and its source.
Good to know: Hold-to-close works on many openers (Genie; Chamberlain/LiftMaster made before February 2022). The door will NOT reverse for anything in its way: clear the doorway and watch it all the way down.
Step by step: Fix garage door sensors (and a door that won't close)
Photos that help
If the safe steps don't sort it, these three photos help a shop quote it in writing:
- Both small sensors near the floor, with their lights showing
- The opener, with any light that is flashing
- The door where it stops
Take them from where you stand. Don't go under the door, and don't touch the springs, cables or tracks. How to send them.
Where this comes from (3 sources)
- Garage Door Opener Light Blinks but The Door Won't Close, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
- Genie Safe-T-Beam System Self Diagnostic Troubleshooting, Genie
- How To Troubleshoot The Safety Reversing Sensors When Both Leds Are Not Lit, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
We read each source on 10 November 2026. The order of causes follows the makers' own troubleshooting pages where they give one; otherwise it is our judgment, and the page says so.
Not quite it? Describe your problem
Describe it in your own words, like "goes back up" or "remote stopped working".
Related problems
- The door starts to close, then goes back up
- The door won't close and the opener lights flash or blink
- The door closes partway and just stops
- The door won't stay closed and ends up open again later
- The door reverses or won't close only when it's cold
- My wall-mounted (side-mount) opener closes the door, then opens it again
Got a quote that feels high?
Text the amount and what it covers to (918) 205-5200. We compare it with published price data (the sources on our price page), and text you back within a business day. Free, no obligation, and we don't repair doors.