My wall-mounted (side-mount) opener closes the door, then opens it again
The likely cause, a quick check, what's safe to do, and what it usually costs.
Most likely: A safety device on the lift cable (tension monitor) senses slack
Chamberlain's code 3-5 for these models covers a door that closes then reverses and says not to operate with a loose cable.
This one needs a garage door company.
Also possible
- Cable tension monitor unplugged, out of place or its roller blocked. The small roller arm that rests on the lift cable is off the cable, or its wire is unplugged. Needs a pro
- Safety sensors misaligned. Work light flashes 10 times and a floor sensor light is off or flickering. DIY
Safe to do now
- Look at both lift cables from a distance; if one looks loose, stop using the door and call a technician.
- If a cable looks loose and you can reach the opener's plug without a ladder and without standing under the door, unplug it so nobody runs the door by accident.
- Read the arrow or light blink code on the opener.
- Check the safety sensors (the two small boxes near the floor) are aligned, with steady lights.
Don't
- Do not operate the door if a cable looks loose.
- Do not touch or re-seat the cable, drum or tension monitor roller yourself.
- Red release cord: only with the door fully closed. Never with a broken spring, loose cable or crooked door.
Battery backup? An opener with a backup battery can still run the door when it is unplugged. Keep everyone clear of the door and keep the remotes out of reach. Your opener's manual says how to disconnect the battery.
Typical price
If it's the most likely cause: Most repairs: typically $98–$371 (across all repairs, including big ones: $98–$860). Source: This Old House, updated May 29, 2026.
If it turns out to be one of the others:
- Opener repair: typically $124–$368 (average $234). Source: HomeAdvisor (no date shown).
National figures, not a quote. Every price range and its source.
Good to know: Codes are for LiftMaster and Chamberlain wall-mount openers such as the 8500W/RJO70. Codes vary by model; check the chart in your manual.
Step by step: Garage door cable snapped: what it means and what to do
Photos that help
These three photos help a shop quote it in writing:
- Both small sensors near the floor, with their lights showing
- The opener, with any light that is flashing
- The door where it stops
Take them from where you stand. Don't go under the door, and don't touch the springs, cables or tracks. How to send them.
Where this comes from (2 sources)
- Garage Door Opener Diagnostic Codes, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
- Residential Jackshaft 3800/8500: Why won't my door close, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
We read each source on 10 November 2026. The order of causes follows the makers' own troubleshooting pages where they give one; otherwise it is our judgment, and the page says so.
Not quite it? Describe your problem
Describe it in your own words, like "goes back up" or "remote stopped working".
Related problems
- The door starts to close, then goes back up
- The door won't close and the opener lights flash or blink
- The door closes partway and just stops
- The door won't stay closed and ends up open again later
- The door reverses or won't close only when it's cold
- The remote or keypad won't close the door, but holding the wall button does
Got a quote that feels high?
Text the amount and what it covers to (918) 205-5200. We compare it with published price data (the sources on our price page), and text you back within a business day. Free, no obligation, and we don't repair doors.