Home / Door stuck? / The door won't close at certain times of day, usually when the sun is low

The door won't close at certain times of day, usually when the sun is low

The likely cause, a quick check, what's safe to do, and what it usually costs.

No rush. Annoying, not dangerous. Fix it when it suits you.

Most likely: Sunlight is shining straight into the receiving sensor

Chamberlain and Genie both say direct sun in the sensor lens can stop the door closing.

Quick check: The problem follows the clock and the weather: the door closes fine at night or on cloudy days.

Try the safe steps first; call a company if they don't fix it.

Also possible

  • Sensor is slightly out of line and sun tips it over the edge. Receiving light flickers a little even on dull days or when the door vibrates. DIY

Safe to do now

  • Note the times it happens and which of the safety sensors (the two small boxes near the floor) the sun hits.
  • Sensor lights steady but the door bows or rubs the frame in heat? See The door bows or curves, especially when the sun is on it.
  • Check alignment and clean both lenses so the beam is as strong as possible.
  • Shade the receiving sensor as our sensor guide shows, or ask about Genie's covered-lens sensor (GSTB-R).

Don't

  • Do not tape over, bypass, raise or disconnect the safety sensors to dodge the sun.
  • Never raise the force setting to push the door shut.

Typical price

If it's the most likely cause: Often free: you can usually sort this yourself.

National figures, not a quote. Every price range and its source.

Step by step: Fix garage door sensors (and a door that won't close)

Photos that help

These three photos help a shop quote it in writing:

  1. Both small sensors near the floor, with their lights showing
  2. The opener, with any light that is flashing
  3. The door where it stops

Take them from where you stand. Don't go under the door, and don't touch the springs, cables or tracks. How to send them.

Where this comes from (2 sources)

We read each source on 10 November 2026. The order of causes follows the makers' own troubleshooting pages where they give one; otherwise it is our judgment, and the page says so.

Not quite it? Describe your problem

Describe it in your own words, like "goes back up" or "remote stopped working".

Related problems

Got a quote that feels high?

Text the amount and what it covers to (918) 205-5200. We compare it with published price data (the sources on our price page), and text you back within a business day. Free, no obligation, and we don't repair doors.

Diagram: Where garage door safety sensors go

A closed garage door seen from inside, with a safety sensor on each side of the opening no higher than 6 inches above the floor, and the beam between them. The sending sensor has an amber light and the receiving sensor a green light on Chamberlain and LiftMaster openers.A closed garage door seen from inside, with a safety sensor on each side of the opening no higher than 6 inches above the floor, and the beam between them. The sending sensor has an amber light and the receiving sensor a green light on Chamberlain and LiftMaster openers.
One sensor on each side, no higher than 6 inches up, aimed at each other. On Chamberlain and LiftMaster openers the receiving sensor shows a green light. Sources: Chamberlain Group support: difference between sending and receiving safety sensors; Chamberlain Group support: how to align safety reversing sensors; Genie: sunlight and Safe-T-Beam sensors (2022). Free to reuse; please credit us: how to use our diagrams.