A light on one of the floor sensors is blinking, dim or off
The likely cause, a quick check, what's safe to do, and what it usually costs.
Most likely: Sensor is out of line or something blocks the beam
Chamberlain says a steady amber with an off or flickering green is typically misalignment or an obstruction; Genie's 2-blink code says the same.
You can usually fix this yourself.
Also possible
- Wire to the sensor is loose, broken or shorted. A light that stays dark after you've cleared and re-aimed both sensors, or a wire off its terminal or pinched under a staple. Needs a pro
- Sensor has failed. Light never returns even with good wiring and careful aiming. Needs a pro
Safe to do now
- Clear anything between the safety sensors (the two small boxes near the floor) and wipe both lenses gently.
- Loosen the wing nut, aim the lenses at each other until the light is steady, then retighten.
- Look at each sensor wire, hands off. Cut, chewed, loose or pinched: stop there and call a technician.
- Need the door shut meanwhile? See The door only closes if I hold the wall button down the whole way.
Don't
- Do not tape over, bypass, raise or disconnect the safety sensors.
- Do not cut or rewire the sensor wires; leave wiring faults to a technician.
Typical price
If it's the most likely cause: Often free: you can usually sort this yourself.
If it turns out to be one of the others:
- Opener repair: typically $124–$368 (average $234). Source: HomeAdvisor (no date shown).
National figures, not a quote. Every price range and its source.
Good to know: Chamberlain/LiftMaster: the amber light sends and the green one receives. Genie sensors use red and green lights and blink codes. Codes vary by model; check the chart in your manual.
Step by step: Fix garage door sensors (and a door that won't close)
Photos that help
If the safe steps don't sort it, these three photos help a shop quote it in writing:
- Both small sensors near the floor, with their lights showing
- The opener, with any light that is flashing
- The door where it stops
Take them from where you stand. Don't go under the door, and don't touch the springs, cables or tracks. How to send them.
Where this comes from (4 sources)
- How To Troubleshoot The Safety Reversing Sensors When One LED Is Off Or Flickering, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
- Genie Safe-T-Beam System Self Diagnostic Troubleshooting, Genie
- How To Troubleshoot The Safety Reversing Sensors When Both Leds Are Not Lit, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
- How to Align Safety Reversing Sensors, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
We read each source on 10 November 2026. The order of causes follows the makers' own troubleshooting pages where they give one; otherwise it is our judgment, and the page says so.
Not quite it? Describe your problem
Describe it in your own words, like "goes back up" or "remote stopped working".
Related problems
- The door closes partway and just stops
- The door won't stay closed and ends up open again later
- The door reverses or won't close only when it's cold
- The remote or keypad won't close the door, but holding the wall button does
- The door starts to close, then goes back up
- The door won't close and the opener lights flash or blink