My opener is very old and has no safety sensors by the floor
The likely cause, a quick check, what's safe to do, and what it usually costs.
Most likely: Opener made before 1993, before safety devices such as floor sensors were required
DASMA, IDA and Chamberlain all use 1993 (made after 1992) as the cutoff for required entrapment protection.
This one needs a garage door company.
Also possible
- Opener does not reverse on contact. Lay a 2x4 flat under the door and close it; a door that does not reverse fails. Needs a pro
- Maker no longer supports or sells parts for it. Find the brand and model on the opener and check the maker's support site. Needs a pro
Safe to do now
- Check for safety sensors (the two small boxes near the floor) on each side of the door.
- Reversal test: lay a 2x4 board flat under the open door and close it. The door must go back up.
- If it fails or there are no sensors, stop using the opener and work the door by hand until replaced.
- Plan to replace rather than repair a pre-1993 opener.
- By hand: release only with the door fully closed. If it feels heavy, leave it shut and call a technician.
Don't
- Do not keep using an opener that fails the reversal test.
- Do not let children operate or play near a door on an old opener.
- Red release cord: only with the door fully closed. Never with a broken spring, loose cable or crooked door.
Typical price
If it's the most likely cause: New opener, installed: typically $390–$650 (unit plus installation). Source: Thumbtack, updated Jul 1, 2026.
National figures, not a quote. Every price range and its source.
Step by step: Garage door items in your home inspection report, explained
Photos that help
These three photos help a shop quote it in writing:
- The whole door from inside the garage
- The spring above the door, end to end
- The label on the opener (brand and model)
Take them from where you stand. Don't go under the door, and don't touch the springs, cables or tracks. How to send them.
Where this comes from (6 sources)
- TDS 167: Residential Sectional Garage Door and Electric Operator Checklist for Home Inspectors and Consumers (Rev. 4/23), DASMA (Door & Access Systems Manufacturers Association)
- Safety & Maintenance, International Door Association
- Does Chamberlain provide parts or support for Chamberlain and LiftMaster garage door openers made before 1993?, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
- Non-Reversing Automatic Garage Door Openers Are a Hazard (CPSC safety alert), U.S. Consumer Product Safety Commission
- To Save Lives Homeowners Should Replace Non-Reversing Garage Doors, U.S. Consumer Product Safety Commission
- TDS 351: Federal and State Garage Door Operator Legislation, DASMA (Door & Access Systems Manufacturers Association)
We read each source on 10 November 2026. The order of causes follows the makers' own troubleshooting pages where they give one; otherwise it is our judgment, and the page says so.
Not quite it? Describe your problem
Describe it in your own words, like "goes back up" or "remote stopped working".
Related problems
- I don't know how often the door should be checked or serviced
- I heard my opener or door control might be recalled
- The home inspector flagged the garage door or opener
- My new door or opener was just installed and something does not look right
- A hurricane or big storm is coming and I want to brace or secure the door
- My closed door can be lifted from outside by hand
Got a quote that feels high?
Text the amount and what it covers to (918) 205-5200. We compare it with published price data (the sources on our price page), and text you back within a business day. Free, no obligation, and we don't repair doors.