The door closes all the way, touches the floor, then opens again
The likely cause, a quick check, what's safe to do, and what it usually costs.
Most likely: Opener is set to close too far, so it treats the floor as a blockage
Chamberlain lists this first for a door that reverses on touching the floor; Genie gives the same explanation.
Try the safe steps first; call a company if they don't fix it.
Also possible
- Ice, snow or debris on the floor where the door lands. Look along the threshold for grit, ice, a stone or a raised spot under the seal. DIY
- The door itself has a problem. Door also feels heavy, jerky or uneven when a technician runs it by hand. Needs a pro
- Fault in the opener's main circuit board (logic board). Only considered after travel is reset and the door checks out. Needs a pro
Safe to do now
- Sweep the threshold and clear any ice, snow or debris where the door lands.
- Door looks sound? Reset down travel (how far the door moves) by your manual, or have a technician do it.
- Lay a 2x4 flat on the floor under the middle of the door and close it: the door must stop and go back up.
- If the reversal test fails, stop using the opener and call a technician.
Don't
- Do not raise the force setting to make the door stay down.
- Do not skip the reversal test after adjusting travel.
Typical price
If it's the most likely cause: Opener repair: typically $124–$368 (average $234). Source: HomeAdvisor (no date shown).
If it turns out to be one of the others:
- Often free: you can usually sort this yourself.
- Most repairs: typically $98–$371 (across all repairs, including big ones: $98–$860). Source: This Old House, updated May 29, 2026.
National figures, not a quote. Every price range and its source.
Step by step: Garage door stops short or reverses? Reset the travel limits
Photos that help
These three photos help a shop quote it in writing:
- Both small sensors near the floor, with their lights showing
- The opener, with any light that is flashing
- The door where it stops
Take them from where you stand. Don't go under the door, and don't touch the springs, cables or tracks. How to send them.
Where this comes from (5 sources)
- Door travels MORE than 6-8 inches, stops and/or reverses, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
- Garage door won't open or close? Try these tips, Genie
- Chamberlain 8200 1/2 HP User Manual, page 35 (Having a problem?), Chamberlain owner's manual (copy hosted by ManualsDir)
- What would cause the door to come down, hit the floor and reverse, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
- How to Test the Safety Reversal System, Chamberlain Group (LiftMaster, Chamberlain and Craftsman support)
We read each source on 10 November 2026. The order of causes follows the makers' own troubleshooting pages where they give one; otherwise it is our judgment, and the page says so.
Not quite it? Describe your problem
Describe it in your own words, like "goes back up" or "remote stopped working".
Related problems
- The door closes partway and just stops
- The door won't stay closed and ends up open again later
- The door reverses or won't close only when it's cold
- The remote or keypad won't close the door, but holding the wall button does
- The door starts to close, then goes back up
- The door won't close and the opener lights flash or blink
Got a quote that feels high?
Text the amount and what it covers to (918) 205-5200. We compare it with published price data (the sources on our price page), and text you back within a business day. Free, no obligation, and we don't repair doors.